This article is included in your selections.

Metal halide lighting sources are not allowed in Zones 1 and 2, and all other light sources must have a color temperature of less than or equal to 3,200K. Any facility in any Zone that is located within 150 feet of a residential property line must utilize light sources with a color temperature of less than or equal to 3,200K. All non-security lighting shall be turned off within 1-hour after the completion of the last service/event. Any fixtures located within 30 feet of a residential property line shall be included in the fixtures being turned off. All non-security outdoor lighting shall be automatically controlled by the equivalent of a 7-day timer, and programmed so that the lighting only activates on evenings when the facility is actually in use. In the event that the parking lot is sized for peak usage (holidays, etc.), control of the lighting is to be divided into “Tiers”, so that the parking lot lighting in the peak-usage areas only operates during those peak times of the year.